Control Company 0.00 to 1999 (µS) and 0 to 199.9 (mS) Traceable® Expanded-Range Conductivity/TDS Meter
Price: | | | 1 | $315.67 | | 2 9 | $299.89 | | 10 23 | $284.10 | | 24 + | $268.32 |
|
|
Traceable® Expanded Range Conductivity Meter
Accurate answers in five seconds Conductivity meter automatically selects the proper range and displays the exact answer with ease. Unit fulfills requirements for CAP, ASTM, NCCLS, CLSI, ACS, CLIA, AOAC, EPA, APHA, AWWA, WEF, USGS, USP, ISO, and Federal/State regulations.
Perfect water tester Use this meter to check the purity of water from stills, deionizers, and reverse osmosis, to test laboratory glassware rinsing, to measure total dissolved solids, and to make solutions. Specifically designed to measure conductivity in water analysis, biology, chromatography, food, electronics, dairies, and PC board rinsing. Labs wanting to maintain accreditation must perform a periodic check of water purity. Unit is 100% compatible with all accreditation analysis requirements.
Simply turn on, insert probe, and simultaneously read result and temperature. Easiest unit ever designed for routine analysis and quality control. Elimination of operator technique permits everyone in the lab to report identical readings. Tough, chemical-resistant ABS plastic housing assures a long life in severe lab or harsh plant environments. Large 1/2-inch-high LCD is easy to read.
Unit permits auto-range or user selected five unique ranges. Complete range is 0.00 to 200,000 microsiemens (micromhos) and 0.0 to 100,000 dissolved solids/parts per million. Accuracy is ± (1% of full scale +1 digit). Switchable temperature range is 0.0 to 80.0°C (32.0 to 176.0°F) with a resolution of 0.1° and an accuracy of 0.6°C. Backlit dual display shows answer and temperature simultaneously. Memory stores up to five unique calibration settings, one in each range. Arrow keys allow fast calibration to solution standards. All calibration data is saved even when unit is turned off. Instant-response glass probe contains platinum electrodes for precise readings. Solid-state thermistor (for automatic/manual temperature compensation) permits all readings to be referenced to the international standard of 25°C. Automatic (2% per °C) temperature compensation or user may set temperature coefficient from 0.000 to 10.000% per °C. Temperature compensation disable function fulfills USP-NF (United States Pharmacopoeia, National Formulary, 645 Conductivity Measurement) requirement. K-factor may be adjusted to match each probe. Total dissolved solids factor is adjustable from 0.4 to 1.
To assure accuracy an individually serial-numbered Traceable® Certificate is provided from our ISO 17025 calibration laboratory accredited by A2LA. It indicates traceability to standards provided by NIST (National Institute of Standards and Technology). HOLD button freezes the reading on the display. Computer output permits connecting to a computer. Probe is 6 x 1/2 inches in diameter with a cable length of 39-1/4 inches. Size is 2-3/4 x 6-3/4 x 1-1/8 inches. Weight is 6-1/2 ounces. Probe, batteries, and rigid carrying care are supplied. Replacement battery Cat. No. 1105.
Specification
Conductivity/TDS Meter
Product Type
Control Company
Brand
Class
Grade
Capacity
Range
Resolution
±1% +1 digit
Accuracy
Precision
0.0 to 80.0°C / 32.0 to 176.0°F
Temperature Range
0.1°
Temperature Resolution
0.6°C
Temperature Accuracy
Humidity Range
Humidity Accuracy
Humidity Resolution
Graduation Range
Graduation Interval
0.00 to 19.99, 0.0 to 199.9, 0 to 1999 (µS) and 0 to 19.99, 0 to 199.9 (mS)
Conductivity
Resistivity
Salinity
0.00 to 9.99, 0.0 to 99.9, 0 to 999 (ppm), 0 to 9.99, 0 to 99.9 (ppt)
TDS
Tolerance (±)
Stopper
Length
Color Code
Readability
Repeatability (S.D.)
Linearity (±)
Pan Size
Units of Measurement
Interface
Calibration
Display
Housing
Draft Shield
Draft Shield Dimensions
Porosity
Pore Size
Disc Diameter
Immersion
(Yes) 2% per °C
ATC
Speed
Speed Increment
Orbit Size
Platform Dimensions
Operating Modes
Max. Flow (GPH)
Max. Flow (GPD)
Max. Pressure (PSI)
Max. Viscosity (cps)
Max. Strokes per Minute
Flow Control
Turn Down Ratio
Head / Fittings
Valve Balls
Diaphragm
Valve / Seat / O-ring
Connections
Motor
Power Supply
Filtration Properties
Basis Weight
Retention Rate
Herzberg Rate
Thickness
Capillary Rise
Pressure Drop
Penetration
Ash Content
Field of View
Emissivity
6 x 1/2 inch Diameter
Probe Length
39-1/4 inches
Cable Length
Max. Time
Timing Capacity
Timer Channels
Timing Functions
Max. Controlled Time Settings
Hold Button
Notes
Probe, batteries, and rigid carrying case
Includes
2-3/4 x 6-3/4 x 1-1/3 inches
Unit Size
Pack Quantity
Case Quantity
Packaging
Overall Dimensions

|
|
|
|