Lovibond® hydrosense Legionella Swab (Biofilm) Test Kit (5 Tests)Within a water system Legionella usually grow within biofilm (slime) found on the insides of pipe work, shower heads, cooling tower packing, or water tanks. Bacteria found in the planktonic phase (i.e. suspended in the water itself) are usually an indicator of colonization of the biofilm.
Since a clean water sample does not equate to a clean system (proliferation of Legionella is greater in a biofilm than in water), this kit can be used to pinpoint the contamination in a system or to demonstrate cleanliness of an area after a targeted cleaning.
Use this kit to find Legionella in their breeding ground — this very selective test can detect Legionella even in samples with very high background flora.
With results in 25 minutes, the test allows for immediate understanding and response to the water system conditions. Regular use will increase confidence in your legionella control procedures and reduce risk of outbreaks and litigation!
- For Detecting Legionella in Biofilms (Surface of water tanks, Shower heads, Air conditioning units)
- Sample Type: surface areas
- Sample Volume: N/A
- Sensitivity: 200 CFU per swabbed area
- Pack Size: 5 Tests
- 2 minutes to sample and 25 minute test
Specification
TintometerBrand
MicrobiologyProduct
Test KitsType
Hydrosense Legionella Field TestProduct Line
LegionellaClass
Grade
ASTM Number
ASTM Application
Capacity
200 CFU/I / Swabbed areaRange
Increments
Resolution
Accuracy
Precision
Temperature Range
Temperature Resolution
Temperature Accuracy
Thermometer Fill
Glass Type
Coating
Bottle Fill
Humidity Range
Humidity Accuracy
Humidity Resolution
Graduation Range
Graduation Interval
Conductivity
Resistivity
Salinity
TDS
Tolerance (±)
Stopper
Length
Color Code
Readability
Repeatability (S.D.)
Linearity (±)
Pan Size
Units of Measurement
Interface
Calibration
Calibration Points
Display
Spigot
Quick Connects
Hose Barb Size
Thread Diameter
Cap Size
Material
Housing
Draft Shield
Draft Shield Dimensions
Porosity
Pore Size
Disc Diameter
Immersion
ATC
Speed
Speed Increment
Orbit Size
Platform Dimensions
Operating Modes
Max. Flow (GPH)
Max. Flow (GPD)
Max. Pressure (PSI)
Max. Viscosity (cps)
Max. Strokes per Minute
Flow Control
Turn Down Ratio
Head / Fittings
Head Tubing
Valve Balls
Diaphragm
Valve / Seat / O-ring
Connections
Motor
Power Supply
Filtration Properties
Basis Weight
Retention Rate
Herzberg Rate
Thickness
Capillary Rise
Pressure Drop
Penetration
Ash Content
Field of View
Emissivity
Probe Length
Cable Length
Max. Time
Timing Capacity
Timer Channels
Timing Functions
Max. Controlled Time Settings
Holds
Places
Hole Size
Rows/Columns
Autoclavable
Height
Rim to Plate
Inner Diameter
Outer Diameter
Top I.D.
Stem Length
Stem I.D.
Stem O.D.
Base
Body
Camera Port
Condenser
Custom Fluorescence Filters
Dioptric Adjustment
Eyepieces
Eyepiece Type
Eyepiece Magnification
Fluorescence Filter Cubes
Focusing
Head
Horizontal Base Pole
Illumination
Infinity Optics
Interpupillary Adjustment
Magnification
Nosepiece
Numerical Aperture
Objective Magnification
Objective Type
Optical System
Pod Ring I.D.
Sample Clearance
Stage
Stage Clips
Stage Insert
Stage Plate
Stand
Vertical Base Pole
Vertical Travel
Viewing Head
Warranty
Working Distance
Zoom Range (Primary)
For Models
Notes
5 Test Strips with Dispensing Pipettes, 5 Swabs, Recovery Buffer, 5 Reaction tubes, and instructions in a carrying case.Includes
5 TestsUnit Size
Pack Quantity
Case Quantity
Packaging
Overall Dimensions
Net Weight
Number of tests: | 5 |
Bacteria Detected: | Legionella pneumophila serogroup 1 |
Detection Method: | Lateral flow immunochromatographic assay |
Lower Limit of Detection: | up to 200 CFU per swabbed area |
Test Volume: | 100 μL (exact volume pipette provided) |
Suggested Sample Area: | 10 cm2 |
Test Development Time: | 25 minutes |
Operator Time: | 1 - 2 minutes |
Specificity: | Tested against a wide range of waterborne bacteria, including Acinetobacter calcoaceticus, Aeromonas hydrophila subsp. hydrophila, Bacillus subtilis, Burkholderia cepacia, Citrobacter freudii, Citrobacter koseri, Escherichia coli, Enterobacter cloacae, Klebsiella oxytoca, Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas putida, Pseudomonas stutzeri, Ralstonia pickettii, Raoultella terrigena, Streptococcus pyrogenes, Yersinia ruckeri. No cross reactions observed at concentrations ≤109 CFU/L.
Staphylococcus aureus has been observed to cross react with the test at concentrations >108 CFU/L.
Legionella pneumophila serogroups 4 & 7 cross react with the test at concentrations > 6×109 CFU/L. The test does not react with any other L. pneumophila serogroups or L. species tested. |
Biocides: | The product has been tested with a range of common biocides and biodispersants used in Legionella control, at their normal maximum operating concentration. Active ingredients tested include: glutaraldehyde, didecyl-dimethylammonium chloride, isolthazoles, ibromonitrilopropionamide, ionic and non-ionic surfactants.The test gives a false positive if used with polymeric biguanide or THPS. |
Shelf Life: | 18 Months from manufacture (stored at room temp. (<30°C) in original packaging). |