Pulsatrol MB9600 Series Boiler Controller.Conductivity Condensate / pH Control.4-20mA Inputs/Outputs: 4 Inputs, 4 Outputs.
Relay & Power Wiring: Conduit (Standard).
pH Sensor Type: Self cleaning pH, preamplifier with power supply (extension cable required).
Language: English (Standard).
Communications: Communications with modem and software.
Agency Approval: None.
Panel Assembly: Conductivity panel, conduit.
MB9600 controllers accurately control the level of dissolved solids based on µS/cm on a timed, held or continuous sample basis. Features four selectable timers, alarm output relay, dry contact alarm output, two water meter totalizers (dry contact or hall effect), four single point drum level inputs, and SS sensor.
Includes: SS sensor, mounting hardware and instruction manual.
Pulsatrol MB9600 Series boiler system controller will provide microprocessor based control of a boiler system. Accurately control the level of dissolved solids based on µS/cm on a timed, held or continuous sample basis, and on select models, control of alkalinity of system water in units of pH. A manually entered data collection field with five user defined fields and units, stored in controller's history. All continuously monitored sensor input functions (conductivity) will provide user definable set points for maintaining a specific value within the system. Each set point will have a user definable differential as the control band, programmable high and low alarm points and user defined limit timer for the control function.
Features:
Four single-point drum level inputs.
Four chemical timers with seven selectable modes. Modes: Percent, Limit, Percent of Post-Bleed with Limit Timer, Pulse Timer, Cycle Timer, Slave Timer, Disabled.
Stainless steel RTD conductivity sensor.
One point calibration.
Calibration date/time stamp.
Alarm powered and dry contact relays.
Relay, drum level alarm, general alarm, flow alarm and power status LED's.
Multiple security levels and lockable viewing window.
Self charging capacitor to maintain time and history for up to two weeks in the event of a power loss to controller.
EEPROM protection of operating parameters during extended power outages.
PULSAtrol MB9600 Boiler Controller DatasheetPULSAtrol MB9600 Boiler Controller and Accessories Selection GuidePULSAtrol MB9600 Boiler Controller Instruction ManualPULSAtrol MB9000 Series Parts
| American Recovery and Reinvestment Act |
Pulsafeeder is compliant with the American Recovery and Reinvestment Act. Buy American, Buy Pulsafeeder Products from Nova-Tech International More Information (PDF - 190KB) |
Specification
Product Type
PULSAtrol
Brand
Class
Grade
Capacity
Range
Resolution
Accuracy
Precision
Temperature Range
Temperature Resolution
Temperature Accuracy
Humidity Range
Humidity Accuracy
Humidity Resolution
Graduation Range
Graduation Interval
Conductivity
Resistivity
Salinity
TDS
Tolerance (±)
Stopper
Length
Color Code
Readability
Repeatability (S.D.)
Linearity (±)
Pan Size
Units of Measurement
Interface
Calibration
Display
Housing
Draft Shield
Draft Shield Dimensions
Porosity
Pore Size
Disc Diameter
Immersion
ATC
Speed
Speed Increment
Orbit Size
Platform Dimensions
Operating Modes
Max. Flow (GPH)
Max. Flow (GPD)
Max. Pressure (PSI)
Max. Viscosity (cps)
Max. Strokes per Minute
Flow Control
Turn Down Ratio
Head / Fittings
Valve Balls
Diaphragm
Valve / Seat / O-ring
Connections
Motor
Power Supply
Filtration Properties
Basis Weight
Retention Rate
Herzberg Rate
Thickness
Capillary Rise
Pressure Drop
Penetration
Ash Content
Field of View
Emissivity
Probe Length
Cable Length
Max. Time
Timing Capacity
Timer Channels
Timing Functions
Max. Controlled Time Settings
Notes
Includes
Unit Size
Pack Quantity
Case Quantity
Packaging
Overall Dimensions