TAY-K-2006C-SALT

(0)No Reviews yet
$277.59 $373.11
QuantityPrice
1 – 1$373.11
1 – 1$277.59
2 +$269.01
SKU: TAY-K-2006C-SALT

New

Taylor Complete Test Kit for Chlorine, pH, Alkalinity, Hardness, CYA, Salt (FAS-DPD–high range) (2 oz bottles)

The 2000 Series™ was designed to permit users to build up their test kits in a stepwise fashion as their testing needs grow without having to purchase duplicate components. Thanks to this upgrade system, a buyer can begin with the fundamentals in the Starter kit and build his way to a comprehensive testing tool called, appropriately enough, the Complete kit.

Options in the 2000 Series include high- or low-range sanitizer values, .75 oz. or 2 oz. reagent bottles, and kits in Spanish. All cases feature a piano-style interlocking hinge and a handle for easy transport.

The heart of any test kit is the comparator block, used for obtaining the water sample, mixing the reagents, and matching colors. Ours are the finest available. Advantages include raised fill marks to help ensure proper test volumes; frosted backing for uniform color perception; and dilution guides that make dealing with high concentrations a breeze. In 2012 we improved the visibility of the CYA test scale by adding a flange, and we resized the large comparator tube to work with our optional sample-sizing tools #6190 and #6191.

Several of the kits in this series feature FAS-DPD drop tests, which can measure free and combined chlorine directly as low as 0.2 ppm. The reading is made by noting a distinct change from vibrant pink to colorless in the reacted water sample. This method is also beneficial when testing samples with a high level of sanitizer (>3–20 ppm chlorine) because there is no need to interpret close shades of pink. The method is a boon for colorblind users too.

All kits include a copy of Pool & Spa Water Chemistry: A Testing & Treatment Guide. Written by experts in water chemistry, this waterproof booklet contains information about sanitation and water balance, as well as tables for water treatment.

AnalyteSystemMethod/ChemistryStandard/Equivalence or DescriptionComparatorCell
Alkalinity, TotalDrop testBlended indicator1 drop = 10 ppm total alkalinity as CaCO₃9058NA
Chloride (Sodium Chloride)Drop testArgentometric (.75 oz)1 drop = 200 ppm NaClNA9198
Chlorine, Free & CombinedDrop testFAS-DPD1 drop = 0.2 or 0.5 ppm chlorine (Cl₂)9058NA
Cyanuric AcidVisual determinationTurbidimetric30, 40, 50, 60, 70, 80, 90, 100 ppm CYA9058NA
Hardness, CalciumDrop testEDTA titration (includes inhibitors to prevent metal interference)1 drop = 10 ppm calcium hardness as CaCO₃9058NA
pH w/ acid/base demand2000 Series comparatorPhenol red7.0, 7.2, 7.4, 7.6, 7.8, 8.09058NA


Product Type: Test Kit
Brand: Taylor Technologies
Product Line: 2000 Series (2 oz)
Class: Alkalinity, Chlorine (high range), Cyanuric Acid, Hardness, Sodium Chloride, pH
Range: Multi
Includes: 1 of the 2004B: BOOKLET,P/S WATER CHEM,EN 1 of the 2107: LABEL,1 1/16 DIA PMS 165 1 of the 5140: INSTR(NEW VERSION),K-2006 1 of the 6026: WATER BAL CALC,WTRGM 0.0031 of the 7015: FOAM 54 X 24 X 1" P/E 1 of the 7043: CASE,SERVICE,TOP/BOTTOM 1 of the 7045: CASE,SERVICE,HANDLE 1 of the 7293: LABEL,BLANK,K-2005C SERIE 1 of the 8155: KIMPAK 7009 CASE 1 of the 9058: 2000 SERIES COMPAR,BR&CL 1 of the 9191: BOTTLE,CAL(7&14 ML),.75 OZ 1 of the 9198: SAMPLE TUBE,GRAD(25 ML) W 1 of the 9500: PIPET W/ INSTR,GIFT OF TI 1 of the R-0003-C: DPD RGT #3,2 OZ,DB 1 of the R-0004-C: PH IND SOL(2000 SERIES),2 OZ 1 of the R-0005-C: ACID DEMAND RGT(2000 SERIES) 1 of the R-0006-C: BASE DEMAND RGT(2000 SERIES) 1 of the R-0007-C: THIOSULFATE N/10,2 OZ,DB 1 of the R-0008-C: TOTAL ALKALINITY IND,2 OZ 1 of the R-0009-C: SULFURIC ACID .12N,P/S,2 OZ 1 of the R-0010-C: CALCIUM BUFF(2000 SERIES) 1 of the R-0011L-C: CALCIUM IND LIQ,2 OZ,DB 1 of the R-0012-C: HARDNESS RGT,2 OZ,DB 3 of the R-0013-C: CYANURIC ACID RGT,2 OZ,DT 1 of the R-0630-C: CHROMATE IND,2 OZ,DB 2 of the R-0718-C: SILVER NITRATE RGT,200 PP 2 of the R-0870-I: DPD PDR,10 G 1 of the R-0871-C: FAS-DPD TITR RGT,2 OZ,DB
Notes: Taylor items have a lead time of 3-15 days.

Click Here to go to Taylor Technologies web site for additional product information.




Ratings & Reviews

No reviews available

Be the first to Write a Review