TAY-K-1805
Images are for representation only. Actual product may differ in size, color or options.
Taylor Drop Test Kit, Molybdenum, Complexometric, 1 drop = 2, 5, 20, or 50 ppm
Molybdenum-based corrosion inhibitors are used in both boilers and cooling towers. In these aqueous systems, molybdenum combines with oxygen to form molybdate. Molybdate inhibits corrosion of low carbon steel. Taylor offers two drop tests to determine both low and high concentrations. Results can be expressed as either molybdenum, molybdate, or sodium molybdate.
Note: The liquid indicator R-0891 in the K-1805 has a limited shelf life and should be checked against Molybdenum Standard (R-0887) periodically after it is four months old. A more stable, two-part reagent system replaces R-0891 in the K-1805P. This liquid/powder combination can be made up on a test-by-test basis or in small quantities.
Molybdenum-based corrosion inhibitors are used in both boilers and cooling towers. In these aqueous systems, molybdenum combines with oxygen to form molybdate. Molybdate inhibits corrosion of low carbon steel. Taylor offers two drop tests to determine both low and high concentrations. Results can be expressed as either molybdenum, molybdate, or sodium molybdate.
Note: The liquid indicator R-0891 in the K-1805 has a limited shelf life and should be checked against Molybdenum Standard (R-0887) periodically after it is four months old. A more stable, two-part reagent system replaces R-0891 in the K-1805P. This liquid/powder combination can be made up on a test-by-test basis or in small quantities.
Analyte | System | Method/Chemistry | Standard/Equivalence or Description | Comparator | Cell |
---|---|---|---|---|---|
Molybdenum | Drop test | Complexometric | 1 drop = 2, 5, 20, or 50 ppm Mo | NA | 9198 |
Product Type: | Test Kit |
Brand: | Taylor Technologies |
Product Line: | Drop Test |
Class: | Molybdenum |
Range: | 1 drop = 2, 5 , 20 or 50 ppm |
Includes: | 2 of the 4030: PIPET,CAL(0.5&1.0 ML) W/ 1 of the 4078: PIPET,GRAD(3 ML) 1 of the 5375: INSTR,DT,MO,K-1805,DR=2/5 1 of the 7060: CASE,DT,RIB,11.5X5.125X2, 1 of the 7265: LABEL,CASE,DT/SC,8.5X2.5 1 of the 8126: KIMPAC 4.75 X 11 2 of the 9198: SAMPLE TUBE,GRAD(25 ML) W 1 of the R-0887-C: MOLYBDENUM STD 20 PPM,2 O 1 of the R-0890-C: MOLYBDENUM BUFF SOL,2 OZ 1 of the R-0891-C: MOLYBDENUM IND SOL,2 OZ 1 of the R-0892-C: MOLYBDENUM TITR SOL,2 OZ, |
Notes: | Taylor items have a lead time of 3-15 days. |
Click Here to go to Taylor Technologies web site for additional product information.