Taylor Drop Test Kit, Chlorine (total), 1 drop = 1 ppm
Chlorine is used as a sanitizer, oxidizer, and bleaching agent in many commercial, industrial, and recreational applications. Colorimetric methods employ either N,N-diethyl-pphenylenediamine (DPD) for testing free and total chlorine or orthotolidine (OT) for determining total chlorine only. Titrations use either the ferrous ammonium sulfate (FAS-DPD) method or the iodometric method for testing free and combined chlorine. The FAS-DPD method is popular with people who have difficulty matching shades of red, as its endpoint is signaled by a distinct change from a color to colorless.
Combined chlorine (CC) can be determined by subtracting the free chlorine (FC) reading from the total chlorine (TC) reading: TC - FC = CC.
Note: These tests are limited to on-site analysis. High chlorine, usually over 10 ppm, may partially or totally bleach out DPD indicator and may turn OT indicator dark brown; if this happens, the sample should be diluted and the test result multiplied by the appropriate factor. Bromine, iodine, and oxidized manganese will register as chlorine.
Description of Tests | |||||||||||||
|
Chlorine is used as a sanitizer, oxidizer, and bleaching agent in many commercial, industrial, and recreational applications. Colorimetric methods employ either N,N-diethyl-pphenylenediamine (DPD) for testing free and total chlorine or orthotolidine (OT) for determining total chlorine only. Titrations use either the ferrous ammonium sulfate (FAS-DPD) method or the iodometric method for testing free and combined chlorine. The FAS-DPD method is popular with people who have difficulty matching shades of red, as its endpoint is signaled by a distinct change from a color to colorless.
Combined chlorine (CC) can be determined by subtracting the free chlorine (FC) reading from the total chlorine (TC) reading: TC - FC = CC.
Note: These tests are limited to on-site analysis. High chlorine, usually over 10 ppm, may partially or totally bleach out DPD indicator and may turn OT indicator dark brown; if this happens, the sample should be diluted and the test result multiplied by the appropriate factor. Bromine, iodine, and oxidized manganese will register as chlorine.
Product Type: | Test Kit |
Brand: | Taylor Technologies |
Product Line: | Drop Test |
Class: | Chlorine (total) |
Range: | 1 drop = 1 ppm |
Includes: | 1 of the 4026: DIPPER SPOON,2 G,WHT 1 of the 4030: PIPET,CAL(0.5&1.0 ML) W/ 1 of the 5376: INSTR,DT,CL,DR=1 PPM 1 of the 7060: CASE,DT,RIB,11.5X5.125X2, 1 of the 7265: LABEL,CASE,DT/SC,8.5X2.5 1 of the 8126: KIMPAC 4.75 X 11 1 of the 9198: SAMPLE TUBE,GRAD(25 ML) W 1 of the R-0636-C: STARCH IND SOL,2 OZ,DB 1 of the R-0664-C: BLEACH RGT #1,2 OZ 1 of the R-0665S-II: BLEACH RGT #2,50 G 1 of the R-0747-C: SODIUM THIOSULFATE,2 OZ,D |
Notes: | Taylor items have a lead time of 3-15 days. |